D292104.9a.fm
System Alarm Messages
Chapter 7: Troubleshooting
7-11
Vision Error System Alarm
The
2D Inspection System
is mounted on the
Taper
between the
place point and the
Sealer
. It inspects parts for mark and orienta-
tion. It also detects empty pockets
If the
2D Inspection System
detects an inspection error, the
2D
Inspection System Alarm
will be activated. Tape advance stops,
a beep sounds and a warning appears on the HMI.
To clear the
Vision Error
system alarm, re-orient or replace the failed part under the
2D Inspec-
tion Camera
. Press
CONTINUE
to clear the alarm and resume operation.