Adjusting PSA Seal Quality
Chapter 7: Troubleshooting
7-29
Adjusting PSA Seal Quality
If a
Peel Force Test
determines the
PSA Sealer
is not generating a satisfactory seal, try one of
the adjustments below to improve seal strength.
Check Sealer Settings
Open the HMI
Taper Tab
. Review
the settings on the four
Taper
Tab
screens to ensure
Tape Settings
and
Sealer Settings
are appropriate for
the current job.
Materials Used
For a
PSA seal,
seal strength is
determined first by the nature of the
materials used. It is normally recom-
mended to use the same brand of
cover and carrier tapes together as
the manufacturers use the appropri-
ate adhesive to match the material
used to make the carrier tapes.
Seal Roller Pressure
The second factor in PSA seal strength is the pressure applied to the cover tape as it is sealed to
the carrier tape. The seal should appear as a solid stripe and it should not show any inconsisten-
cies. If it does, the alignment of the cover tape should be confirmed and then the pressure to the
seal rollers adjusted.
On the top of each sealer block, there are three
holes with a screw in the center hole. With carrier
and cover tape loaded, spin the
Sealer Wheel
.
While spinning the
Sealer Wheel,
turn the screw
clockwise until the wheel no longer spins freely,
then turn the screw another 1/8 turn. The wheel
should be firmly in contact with the tape.
Adjust the seal roller pressure until the PSA
adhesive is firmly adhered to the carrier tape.
Experience will allow the operator to judge the correct adjustment by feel. Repeat for the other
sealer wheel.
Note:
Excessive roller pressure may cause carrier tape advance problems or elongation
of sprocket holes in the carrier tape.
PSA Seal
Adjustment
Screws
Pressure
Summary of Contents for TM-401
Page 4: ......
Page 74: ...3 32 TM 401 User s Guide Run Tab D292104 6 fm ...
Page 146: ...5 44 TM 403 User s Guide Configure Inspection D292104 16 fm ...
Page 158: ...6 12 TM 401 User s Guide Preparing to Run a Pre programmed Job D292104 8a fm ...
Page 188: ...7 30 TM 401 User s Guide Adjusting PSA Seal Quality D292104 9a fm ...
Page 204: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D292104 11 fm ...
Page 208: ......
Page 284: ......
Page 286: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 288: ...TM 401 Document List D292104 15b fm Page 2 ...
Page 290: ......
Page 291: ......