7-14
TM-401 User’s Guide
System Alarm Messages
D292104.9a.fm
Heat Sealer Inactivity System Alarm
If the
Taper
is inactive for 40 minutes or longer, the
Heat Sealer
is automatically disabled. Once
that occurs, if a user attempts to run a job, or use
Continuous Advance, Pocket Advance
or
Man-
ual Seal
a
Heat Sealer Inactivity
system alarm will activate.
When this occurs,
tape advance stops, a beep sounds and a warning appears on the HMI.
To clear the
Heat Seal Inactivity System Alarm
, wait for the heat shoes to reach their set point
and then press
CONTINUE
to clear the alarm and resume operation. The current temperature is
displayed on the system alarm message.
Note:
If the user presses
Continue
and then attempts to move tape through the sealer
before the temperature has reached the set point, the
Temperature Out Of Range
system
alarm will appear, prompting the user to wait until the sealer temperature is correct.