D292104.9a.fm
Tips on Part Placement
Chapter 7: Troubleshooting
7-25
5.
Adjust Blow Off Time.
Press the right
Arrow
button on the bottom of the second
Head
Tab
to move to the last
Head Tab
screen
6.
Adjust the length of
Blow Off
as needed to drop the part properly.
Note:
If
Nozzle Blow Off
is set too low, the part may remain on the
Nozzle Tip
or “float”
down, resulting in an incorrectly placed part in the pocket.
If
Nozzle Blow Off
is set too high, the excess air may cause the part to bounce back out of
the pocket. Adjust the
Nozzle Blow Off
value until the TM-401 consistently and accurately
places parts in the carrier tape.