7-20
TM-401 User’s Guide
System Alarm Messages
D292104.9a.fm
Error Message Table
Error Condition
Solution
“The system was unable to suc-
cessfully pick from the feeder.”
Nozzle is not picking parts from the
Tube Feeder
. Check
the following:
- Feeder is empty.
- Tube Feeder is jammed.
- Pick height is too high.
“The heat seal temperature is
not within range.”
The
Heat Sealer
on the
Taper
has not reached the cor-
rect temperature. Wait until sealer has had enough time
to reach the correct temperature.
“The heat sealer was disabled
due to inactivity.”
The
Heat Sealer
on the
Taper
was automatically disabled
after being inactive for more than 40 minutes. Wait until
sealer has had enough time to reach the correct temper-
ature, then proceed.
“The tape jam sensor has been
activated.”
Check carrier tape prior to
Sealer
to ensure part is not
sticking out of pocket. Remove any obstructions, then
resume operation.
“The cover tape is running low.”
Refill cover tape.
“A part has failed visual inspec-
tion in the carrier tape.”
Check the following:
- Part is incorrectly oriented.
- Part
Mark
is missing or obscured.
- Part is missing.
“The vision system has timed
out.”
Check the following:
- Vision system is not connected to power
- Vision System is setup incorrectly.
“The last part picked was lost
between the pick and place
point.”
Check the following:
-
Vacuum Sensor
is set correctly.
- The correct
Nozzle Tip
is installed.
-
Pick Position
is centered correctly.
“The system has already placed
more parts than the entered
quantity.”
The job quantity was changed after parts have been run.
Reset job or increase quantity.
“There’s not a part available to
place.”
Pick a part and proceed.
“The job has been completed.
Reset the job to continue pro-
cessing.”
Reset the job.
Summary of Contents for TM-401
Page 4: ......
Page 74: ...3 32 TM 401 User s Guide Run Tab D292104 6 fm ...
Page 146: ...5 44 TM 403 User s Guide Configure Inspection D292104 16 fm ...
Page 158: ...6 12 TM 401 User s Guide Preparing to Run a Pre programmed Job D292104 8a fm ...
Page 188: ...7 30 TM 401 User s Guide Adjusting PSA Seal Quality D292104 9a fm ...
Page 204: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D292104 11 fm ...
Page 208: ......
Page 284: ......
Page 286: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 288: ...TM 401 Document List D292104 15b fm Page 2 ...
Page 290: ......
Page 291: ......