7-8
TM-401 User’s Guide
System Alarm Messages
D292104.9a.fm
Part Lost System Alarm
If a part falls off the nozzle and is lost during the Pick process, the
Part Lost
system alarm will be
activated. When this happens, operation stops, a beep sounds, and a warning appears on the
HMI.
To clear the
Part Lost System Alarm,
check the
Vacuum Sensor
to ensure it is set correctly. Next,
ensure the correct
Nozzle Tip
for the part that is being picked is installed. Finally, check the
Pick
Position
to ensure it is centered correctly. Adjust as necessary.
When the
Tube Feeder
is ready for operation, press
CONTINUE
to clear the alarm and resume
operation.
Summary of Contents for TM-401
Page 4: ......
Page 74: ...3 32 TM 401 User s Guide Run Tab D292104 6 fm ...
Page 146: ...5 44 TM 403 User s Guide Configure Inspection D292104 16 fm ...
Page 158: ...6 12 TM 401 User s Guide Preparing to Run a Pre programmed Job D292104 8a fm ...
Page 188: ...7 30 TM 401 User s Guide Adjusting PSA Seal Quality D292104 9a fm ...
Page 204: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D292104 11 fm ...
Page 208: ......
Page 284: ......
Page 286: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 288: ...TM 401 Document List D292104 15b fm Page 2 ...
Page 290: ......
Page 291: ......