Locking the Keys
It is sometimes desirable to lock the keys of the sensor amplifiers so that the currents settings
are not inadvertently changed.
1.
Hold down the
Manual
button and the
Mode
button simultaneously for at least three sec-
onds.
2.
The
CV indicator
will display
Loc
to indicate that the lock is in place.
3.
Repeat the same procedure to unlock the keys. The display will flash the message
unL
.
Two-point Calibration
1.
With an obstructing object between the sensors (ideally, a full reel of cover tape), press
and release the
SET
button. The
PV Indicator
will be lit.
2.
Remove the obstruction between the sensors and press
SET
again. The amplifier will
return to its normal operating mode. The number shown on the
PV Indicator
should
change.
3.
If the sensor is in dark-ON mode, the operation indicator should be lit while there is an
obstruction between the sensors. If the sensor is in light-ON mode, the operation indica-
tor should be lit while there is no obstruction between the sensors.
Summary of Contents for TM-401
Page 4: ......
Page 74: ...3 32 TM 401 User s Guide Run Tab D292104 6 fm ...
Page 146: ...5 44 TM 403 User s Guide Configure Inspection D292104 16 fm ...
Page 158: ...6 12 TM 401 User s Guide Preparing to Run a Pre programmed Job D292104 8a fm ...
Page 188: ...7 30 TM 401 User s Guide Adjusting PSA Seal Quality D292104 9a fm ...
Page 204: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D292104 11 fm ...
Page 208: ......
Page 284: ......
Page 286: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 288: ...TM 401 Document List D292104 15b fm Page 2 ...
Page 290: ......
Page 291: ......