4.2.4.6.47 Object 0x60C5: Maximum acceleration
Object code
VAR
Data type
UNSIGNED32
Attribute
rw
Default
10000
Min
1
Max
2
32
-1
PDO mapping
yes
Description
This parameter specifies the maximum permissible acceleration in user-defined
acceleration units.
4.2.4.6.48 Object 0x60C6: Maximum deceleration
Object code
VAR
Data type
UNSIGNED32
Attribute
rw
Default
15000
Min
1
Max
2
32
-1
PDO mapping
yes
Description
This parameter specifies the maximum permissible deceleration in user-defined
acceleration units.
4.2.4.6.49 Object 0x60FD: Digital inputs
Object code
VAR
Data type
UNSIGNED32
Attribute
ro
Default
0
Min
-
Max
-
PDO mapping
yes
Description
This parameter specifies the current status of the digital inputs.
encoTRive supports the following digital inputs:
Bit 0: lower position value reached (1 = yes, 0 = no)
Bit 1: upper position value reached (1 = yes, 0 = no)