CANopen communication
Printed in the Federal Republic of Germany
©
TR-Electronic GmbH 2007, All Rights Reserved
05/16/2007
TR - EMO - BA - DGB - 0013 - 00
Page 235 of 260
4.2.4.6.34 Object 0x607E: Direction reversal
Object code
VAR
Data type
UNSIGNED8
Attribute
rw
Default
0
Min
0
Max
255
PDO mapping
yes
Description
This parameter defines whether the direction of position and/or speed is to be
reversed.
If a direction reversal is defined, the values of actual position value and nominal
position or actual speed value and nominal speed are multiplied by -1.
The parameter value is interpreted as follows:
Table 31: Direction reversal
Bit 7
Bit 6
Bit 5-0
1 – Direction reversal at
position
0 – No direction reversal at
position
1 – Direction reversal at
speed
0 – No direction reversal at
speed
reserved
4.2.4.6.35 Object 0x607F: Maximum speed
Object code
VAR
Data type
UNSIGNED32
Attribute
rw
Default
7500
Min
0
Max
2
32
-1
PDO mapping
yes
Description
This parameter defines the maximum speed in speed units during a positioning
movement. The speed factor is decisive for the interpretation of the speed unit.
This default value corresponds to 75 rpm.