CANopen communication
©
TR-Electronic GmbH 2007, All Rights Reserved
Printed in the Federal Republic of Germany
Page 196 of 260
TR - EMO - BA - DGB - 0013 - 00
05/16/2007
4.2.4.4.14 Object 0x1015: Inhibit Time for EMCY
Object code
VAR
Data type
UNSIGNED16
Attribute
rw
Default
96
Min
0
Max
65535
PDO mapping
-
Description
This parameter defines the inhibit time for the EMCY message in
0.1 ms steps. Parameter value 100 = 10 ms.
If encoTRive has issued an EMCY message, the next EMCY message may not be
sent before this time has expired. Parameter value 0 = no inhibit time for EMCY.
4.2.4.4.15 Object 0x1016: Consumer Heartbeat Time
Object code
ARRAY
Description
This parameter defines the time interval within which a heartbeat message is
expected. A maximum of two nodes are supported as heartbeat producer.
Subindex 0: Number of entries
Data
type
UNSIGNED8
Attribute
ro
Default
2
Min
-
Max
-
PDO
mapping
-
Description
Contains the largest array subindex
Subindex 1: Consumer Heartbeat Time 1
Data
type
UNSIGNED32
Attribute
rw
Default
0
Min
-
Max
-
PDO
mapping
-
Description
The parameter value comprises two pieces of data:
Bits 31-24
Bits 23-16
Bits 15-0
0
Node ID
Heartbeat time
The heartbeat time defines the time interval within which a
heartbeat message is expected from the node whose node
ID is stored in bits 23-16. A heartbeat time of 0x00 means
that no heartbeat message is expected.