CANopen communication
©
TR-Electronic GmbH 2007, All Rights Reserved
Printed in the Federal Republic of Germany
Page 166 of 260
TR - EMO - BA - DGB - 0013 - 00
05/16/2007
4.2.3.3.2 Status word
Bit STATUS WORD
0 Value 1: Ready to switch on
1 Value 1: Ready for operation
2 Value 1: Operating mode activated
3 Value 1: Error present
4 Value 1: Voltage switched on
5 Value 1: Quick stop active
6 Value 1: Not ready for operation
7 Value 1: Warning present
8 not
used
0
No parameter access
via CAN bus
9 Manual
operation
1
Parameter access
via CAN bus
0
Stop = 0:
Target position not reached
Stop = 1
Axis decelerates
10 Target
reached
1
Stop = 0:
Target position reached
Stop = 1
Axis speed = 0
11
Value 1: Exit working range
Position value outside the preset range.
Definition via object 0x607D.
0
Positioning values not
accepted
12
Acknowledgement of target
position
1 Positioning values accepted
13
Value 1: Tracking error
A tracking error is indicated if the difference between position value and
calculated ramp value is greater than the tracking error window preset in
object 0x6065 for the minimum duration of the time interval specified in object
0x6066 (Tracking Error Timeout).
14-15
not used
Table 15: Status word (object 0x6041), "Positioning ramp" operating mode