CANopen communication
Printed in the Federal Republic of Germany
©
TR-Electronic GmbH 2007, All Rights Reserved
05/16/2007
TR - EMO - BA - DGB - 0013 - 00
Page 195 of 260
Subindex 3: Factory settings for application parameters
Data
type
UNSIGNED32
Attribute
rw
Default
0
Min
-
Max
-
PDO
mapping
-
Description
Configures all parameters from the range 0x6000-0x9FFF,
for which factory settings are available, with their factory
settings. This only occurs if the value
0x64616F6C
is written. This is the numeric value resulting from the "load"
character string ('l' : 0x6C, 'o': 0x6F, 'a' : 0x61, 'd': 0x64).
Subindex 4: Factory settings for manufacturer-specific parameters
Data
type
UNSIGNED32
Attribute
rw
Default
0
Min
-
Max
-
PDO
mapping
-
Description
Configure all parameters from the range 0x2000-0x5FFF, for
which factory settings are available, with their factory
settings. This only occurs if the value
0x64616F6C
is written. This is the numeric value resulting from the "load"
character string ('l' : 0x6C, 'o': 0x6F, 'a' : 0x61, 'd': 0x64).
4.2.4.4.13 Object 0x1014: COB-ID of the EMCY message
Object code
VAR
Data type
UNSIGNED32
Attribute
ro
Default
Node ID + 0x80
Min
-
Max
-
PDO mapping
-
Description
This parameter defines the COB-ID of the EMCY message.
A node with Node ID 0x70 uses as COB-ID for the EMCY message 0x70+0x80 =
0xF0 (240 dec.)