Strata CTX Configuration
CTX100 Maximum Capacity Configuration Examples
Strata CTX I&M 10/02
1-27
Str
a
ta CT
X
C
o
nfigu
ration
with the exception of RDTU and RPTU PCBs that support more than 16 channels, and BDKU/
BDKS PCBs that support Speaker OCA.
3. RDTU and RPTU PCBs can be placed in any odd numbered slot using the following rules:
•
If RDTU or RPTU is placed in Slot 103 (preferred) with 8, 16 or 24 channels, another PCB
can still be installed in S104.
•
If RDTU or RPTU is placed in Slots 101, 105, or 107 with 8 or 16 channels, another PCB
can still be installed in the next slot; however, if 17~24 channels are required the next even
slot must be vacant.
4. Digital telephone PCBs that support Speaker OCA can be placed in slots using the following
rules:
•
If ADKU, BDKU (without BDKS) or PDKU must support Speaker OCA, it can be installed
in any slot; another PCB can be installed in the next even slot.
•
If a BDKU/BDKS PCB must support Speaker OCA it can only be installed in Slot 103;
another PCB can be installed in S104.
CTX100 Maximum Capacity Configuration
Examples
The tables in this section summarize the maximum capacities of digital telephones with various
types of line circuits. A PCB placement diagram for each numbered configuration follows tables.
Digital Telephones and Loop Start Lines With or Without Caller ID
Table 1-11
CTX100 Base Cabinet with Analog, Loop Start Lines
4 Universal Slots
40 Stations (Max.)
24 CO lines (Max.)
44 St Analog loop start lines combined (Max.)
Table No.
Stations
Analog loop start lines
1-12
40
4 (none can have Caller ID)
1-13
32
8 (all can have Caller ID)
1-14
32
16 (none can have Caller ID)
1-15
16
16 (8 can have Caller ID)
1-16
24
1
1. Using ADKU.
8 (none can have Caller ID)
Table 1-12
CTX100 Base: 40 stations, 4 loop start lines, 0 CLID
S101
S102
S103
1
1. S103 is only 8 DKTs and S104 is only 4 lines because of cabinet
power factor
S104
BDKU/
BDKS
BDKU/
BDKS
ADKU
RCOU
16 DKTs
16 DKTs
8 DKTs
4 lines
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...