Station Apparatus
Direct Station Selection (DSS) Console/System Connection
8-28
Strata CTX I&M 10/02
Direct Station Selection (DSS) Console/System
Connection
The DSS console can be connected to a BDKU/BKDS or
PDKU on any circuit. DSS consoles are associated with
digital telephones via system programming. This section
provides instructions on how to install the consoles.
DSS Console Connections
DSS consoles are connected to BDKU/BDKS or PDKU
PCBs using standard twisted single-pair or two-pair jacketed
telephone cable (maximum 1000 feet, 303
meters) is used for
the connection.
To accommodate the DSS console connection, the
instrument end of the cable should be terminated in a
modular station connector block (RJ11). Refer to
Chapter 7 –
MDF PCB Wiring
for wiring/interconnecting details.
Notes
●
DSS console cable runs must not have cable splits (single or double), cable bridges (of any
length) or high resistance or faulty cable splices.
●
See the appropriate Installation chapter for secondary protection information and loop limits.
CAUTION!
When installing the DDSS cable, do not run the cables parallel if they are
within three feet of an AC power line. AC power lines should be crossed at right
(90
°
) angles only. In particular, avoid running station wire pairs near devices
that generate electrical noise, such as neon or fluorescent light fixtures.
5842
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...