Strata CTX Configuration
Worksheet 6: Strata CTX670 Cabinet Slot Configuration
1-38
Strata CTX I&M 10/02
•
Cables are provided according to the connectors on the RRCU card to which they are attached.
See
Table 1-53
for connector information.
Step 3:
BIOU Interface PCB
•
Up to two BIOU PCBs can be installed in any local/remote cabinet slot, except the BIOU may
not occupy a vacant slot adjacent to RDTU or RPTU. See
“Worksheet 4: Page/MOH/Control
Relay” on page 26
for BIOU functions.
Step 4:
T1 Digital Line PCBs
•
See
Worksheet 3: CO Line
to determine RDTU PCB requirements.
•
RDTU must be placed in designated slots as shown in
Table 1-54
. The RDTU PCB can provide
up to 16 or 24 T1 lines. The RDTU slot provides 16 T1 lines, an additional eight lines requires
that the cabinet slot adjacent to RDTU be vacant. Up to 11 RDTU PCBs can be installed in a
fully expanded system
Table 1-53
Remote Cabinet Data Cables and Connectors
Data Cables
RRCU Connectors
M1
S1
M2
S2
BDCL1A-MS1
X
X
BDCL1A-M2
X
BDCL1A-S2
X
X = Applies to connector.
Table 1-54
RDTU PCB Cabinet Slot Configuration
T1 Channels
Needed per
Cabinet
Slots
Needed
RDTU PCBs
Needed
1
1. RDTU PCBs do not have to be installed in the order shown in this table. Example: If only one
RDTU is needed, it can be installed in any RDTU slot shown in the table so long as the slot is
supported by the installed processor.
RDTU cabinet slot placement
1
Base Cabinet
1~16 1
1
S103-RDTU
17~24 2
S104-vacant
2
2. The slot occupied by RDTU supports 1-16 channels; the slot adjacent to RDTU must be vacant
if channels 17 through 24 are needed.
24~40
3
2
S105-RDTU
41~48
4
S106-vacant
2
49~64
5
3
S107-RDTU
65~72
6
S108-vacant
2
Second through seventh cabinets
1~16 1
1
S_01- RDTU
17~24 2
S_02-vacant
2
25~40
3
2
S_03- RDTU
41~48
4
S_04-vacant
2
49~64
5
3
S_05-RDTU
65~72
6
S_06-vacant
2
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...