ISDN Interfaces
RBUU/RBUS Interface Unit
Strata CTX I&M 10/02
5-29
ISDN Inte
rface
s
Table 5-10
Four-Pair with RJ45 Demarc Jack Coding
Table 5-11
Three-Pair with RJ11 Demarc Coding
Notes
●
PS2 and PS3 are not used with the Strata CTX BRI-U interface PCBs.
●
Check with the BRI circuit supplier to determine the pin out of the demarc jacks because some
jacks may be wired with two or three BRI-U line circuits each jack.
Station-Side cabling
•
The ISDN BRI U-interface circuits are two-wire on the Strata CTX station-side.
•
The maximum distance between the Strata CTX ISDN BRI-U, station-side circuit (LT) and the
U-type Terminal Equipment or Terminal Adapter is 18kft.
•
The house wiring from the Strata CTX BRI circuit to the wall jack should be made with CAT3~
CAT5 twisted pair wire.
•
Each station-side BRI circuit requires a ferrite core as shown in
Figure 5-14 on page 5-20
.
•
The flat satin telephone cord that connects from the wall jacks to ISDN terminal equipment
should be no longer than 33 feet.
•
BRI station-side cables should not be shielded.
•
Polarity of the U interface pair is not critical.
•
The U interface pair should go directly from the Strata CTX interface PCB to the U-type TE1
or TA with no bridge taps or loading coils to different locations.
•
The pin-out of the RBUU/RBSU BRI jack is shown in
Figure 5-23
:
Call Monitor Jack Cabling
The pin-out for the BRI-U interface call monitor jack is provided in
Figure 5-30
of this chapter.
Conductor
Color
T56A Pin
T56B Pin
Use
Pair 1
White-Blue
5
5
Line 1
Blue
4
4
Line 1
Pair 2
White-Orange
3
1
Line 2
Orange
6
2
Line 2
Pair3
White-Green
1
3
PS3 plus power
Green
2
6
PS3 minus power
Pair 4
White-Brown
7
7
PS2 plus power
Brown
8
8
PS2 minus power
Conductor
Color
Pin
Use
Pair 1
White-Blue
4
Line 1
Blue
3
Line 1
Pair 2
White-Orange
2
Line 2
Orange
5
Line 2
Pair3
White-Green
1
Line 3
Green
6
Line 3
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...