7. Reinstall the base on the telephone.
Figure 8-6
BHEU Installation
Telephone Option Straps
Certain option straps on the DKT3000-series phones must be cut when installing carbon handsets,
external power or headsets. Refer to
Table 8-6
and
Figures 8-7
~
8-9
for further instruction.
Table 8-6
Station Option Interface PCB Compatibility
Name of the
Strap on the
DKT PCB
DKT3010-S,
DKT3020-S,
DKT3010-SD,
DKT3020-SD
DKT3014-
SDL
DKT3001
Explanation
Carbon
W301, W302
W301,
W302
If a carbon-type handset or carbon-type headset is
connected to the handset jack, the carbon wire jumper
straps, listed on the left, must be cut inside the
telephone. When a carbon headset is connected to the
BHEU, you do not need to cut the straps. See
Figures
8-7
~
8-9
.
HEU
W303
W303
W103
To turn off the handset receiver when the handset is on-
hook and a headset is used with the BHEU, cut the
“HEU” strap shown on the left.
EX.POWER
W101, W102
W101,
W102
W101,
W102
Cut the “EX.POWER” straps only when external power is
connected to the second pair (pins 2 and 5) of the
telephone modular jack. See Chapter 7 – MDF PCB
Wiring,
on page 7-1
.
SET UP
W401, W402
W401,
W402
Do not cut – for factory use only.
Digital
Telephone
Top Assembly
Digital
Telephone Base
Red
Wire
5657
(P3) HEU
BHEU
BVSU or BPCI
(optional)
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...