Strata CTX670 Installation
Remote Expansion Cabinet Unit
Strata CTX I&M 10/02
3-53
Strata
CTX67
0
Inst
alla
tion
Figure 3-37
ROMS1A Subassembly
Table 3-13
Fiber Optic Specification
Item
Specification
Transmission Speed
155.52 Mbps
Optical Source
LED, 1300 nm
Fiber Type
Multi-mode, Graded Index Fiber (GIF)
Core Diameter
62.5 micrometers
Cladding Diameter
125 micrometers
Connector Type
SC (2-pin transmit and receive)
Maximum Fiber Length
3 km (500~1000 MHz/km fiber)
2 km (200~400 MHz/km fiber)
Optical Budget (Loss)
9 dB (one way)
Minimum Bend Radius
30 mm
Round Trip Delay Time
30 micro
seconds.
Transmit Power
>= -23.5 dBm
Receiver Sensitivity
<= -30 dBm
TX Side
RX Side
4379
ROMS1A
SD
RDER
SYCF
SYCS
RST
CD1
CD2
CD3
CD4
CD5
J3
J1
1
15
1
10
J2
J4
1
11
11
1
-24v
DG
PFT-CONTROL
Optical
Module
Plastic
Cap
Remove
Rubber Cap
to plug in
Fiber Optic
Cable
Fiber Optic
Cable
CAUTION!
Inserting the fiber connector
at an angle or too forcefully
can cause damage.
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...