Step 7: Install Processor and Universal PCBs
This section provides procedures for the installation of CTX670 processor (or common control)
PCBs.
The CTX670 system Base and Expansion Cabinets are shipped empty. PCBs are not installed at
the factory. Universal PCBs must be placed according to the configuration information obtained
and developed in Chapter 1 – Configuration. Processor PCB installation is in
Chapter 4 – PCB
Installation
.
•
Install PCBs only after installing the Base Cabinet and, if applicable, Expansion Cabinets per
the Cabinet Installation section in this chapter.
•
Be sure the power supply has been tested and the ground has been checked (see
“Install Power
Supply” on page 3-6
.
•
Install universal slot PCBs per the CTX670 configuration guidelines (see
“Worksheet 6: Strata
CTX670 Cabinet Slot Configuration” on page 1-36
.
•
Install the metal mesh shield, B50MT around the 25-pair cables connected to PCBs per
Figure
3-10
.
PCB Installation Considerations
The Base Cabinet has ten slots. The first two slots, labeled “B101” and “B102” are reserved for the
common control unit and future feature upgrades. The next eight slots (labeled “S101” ~“S108”)
are universal and capable of hosting any of the station, line, and option interface PCBs compatible
with the CTX670 systems.
The Expansion Cabinets have ten universal slots, labeled “S_01,” “S_02,” etc., where the blank
space of the label represents the number of the Expansion Cabinet. Like the universal slots in the
Base Cabinet, these universal slots are capable of hosting any of the station, line, and option
interface PCBs.
Cabinets are numbered from 1 to 7. The Base Cabinet is numbered 1; the first Expansion Cabinet,
number 2; the second Expansion Cabinet, number 3, etc. See the CTX670 Configuration and PCB
Installation section for details.
PCB Option Considerations
CTX670 PCBs can be configured for a variety of hardware and software options. Hardware
options are defined as either internal (generally related to optional PCB subassemblies) or external
(related to connection of peripheral equipment such as background music, voice mail, etc.).
Hardware Options
Some PCBs must be configured for hardware options prior to installation of the PCB in the
cabinet. Configuration instructions for internal hardware options are provided in the individual
PCB installation procedures in this chapter and in
Chapter 4 – PCB Installation
. Configuration
instructions for external hardware options are provided in
Chapter 9 – Peripheral Installation
.
Software Options
PCBs are configured for software options through programming, following the installation
instructions of the PCBs. A programming overview for each PCB is provided in the individual
PCB installation procedures in this chapter. Refer to the Strata CTX Programming Manual for
detailed programming instructions.
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...