Strata
CTX10
0
Ins
talla
tion
Strata CTX100 Installation
Installing the CTX100 Cabinet
Strata CTX I&M 10/02
2-21
Step 10: Install Other PCBs into the Cabinet(s)
1. Each PCB must be configured for the applicable hardware options prior to installation of the
PCB to the CTX100 cabinets.
Configuration instructions for individual PCBs are in
Chapter 4 – PCB Installation
and
Chapter
7 – MDF PCB Wiring
. Configuration instructions for external hardware options are provided in
Chapter 9 – Peripheral Installation
.
2. Use the PCB placement guide in
“Worksheet 5: Strata CTX100 Cabinet Slot Configuration” on
page 1-26
to determine which PCB slot can be used for each PCB type.
3. Slide the PCB Slot Locking Bar to
the right, then insert each of the
PCBs; push the PCBs firmly toward
the motherboard, making sure that
the connectors are secured (see
Figure 2-18
). Lightly tug on each
PCB to make sure that it’s installed
securely.
4. After all the PCBs are installed, slide
the PCB Slot Locking Bar to the left
to lock the PCBs into place.
5. Configure the PCBs for software
options through programming. Refer
to the Strata CTX Programming
Manual for more detailed
programming instructions.
Note
The Base and Expansion cabinets
have four universal PCB slots
each which can accept the same
universal PCBs as the CTX670.
CTX100-only components are
shown in
Table 2-2
.
Table 2-2
CTX100 Cabinet and Processor Components
PCB
Provides
Comments
Installs On
CHSUB112
Base Cabinet with power supply without
battery charger.
Provides 4 universal slots.
CHSUE112
Expansion Cabinet with power supply
without battery charger.
Provides 4 universal slots.
APSU112
Power Supply for CTX100.
Spare power supply.
Base or
Expansion
Cabinet
ACTU
System Processor PCB. (Optional PCB
attachments include: modem. Ethernet
10BaseT, DTMF Receiver/Busy Tone
Detector and Serial Interface Unit.
One per system. Supports 8 PCB
slots (4 slots in the Base C
4 more in the Expansion Cabinet).
ARCS
(Optional)
DTMF Receiver and ABR Circuits.
One per system. Provides 16
DTMF and 16 ABR circuits.
ACTU
AETS
(Optional)
Ethernet LAN (10 BaseT)
One per system. Provides 10Mbps
LAN by one RJ45 for WinAdmin.
ACTU
PCB Slot
Locking Bar
6005
Figure 2-18
PCB Slot Locking Bar
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...