Strata CTX670 Installation
Install Reserve Power
Strata CTX I&M 10/02
3-41
Strata
CTX67
0
Inst
alla
tion
Notes
•
When floor mounting the CTX670, the batteries must be installed by a licensed electrician per
local electric code using conduit. (See
Figure 3-25
.)
•
Batteries should be installed in a customer-supplied commercial battery box or enclosed rack.
To BBDB
Battery Distribution Box
F1~F4 Battery
Fuses 250VAC/15A
BCCB
BATT
-
+
AC
N
L
Battery Wire Specifications
#10 AWG minimum (2 pairs)
42A max.
AC Wire
Specifications:
BCCB120
#10 AWG
29A max.
BBCB240
#12 AWG
18A max.
BCCB120 (top view)
3 outlets
NEMA:5-15R
Fused: 250VAC/15A
Rated: 125VAC/15A
BCCB240 (top view)
2 outlets
NEMA:6-20R
Not Fused
Rated: 250VAC/20A
5047
F3
F1
F4
F2
F3
F1
F4
F2
Conduit
Holes to 1/2 inch trade size
WARNING!
BCCB conduit boxes must be
installed by a certified electrician.
From
reserve
battery
From
20A dedicated
circuit
Figure 3-25
BCCB AC Power and Battery Connections
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...