PCB Installation
RDDU – Direct Inward Dialing Line Interface Unit
Strata CTX I&M 10/02
4-23
PCB In
stal
latio
n
RDDU – Direct Inward Dialing Line Interface Unit
Circuits per PCB:
four DID lines
Interfaces with:
DID (one or two-way) lines
Older Version(s):
none
The RDDU provides four Direct Inward Dialing (DID) lines, each of which can have a single
office code along with a block of extensions.
Each extension can be assigned to ring a station [DN] that appears on one or multiple stations,
Distributed Hunt or ACD Group, or an external telephone number selected in system
programming. This enables calls over the same line to be routed to different stations or groups of
stations. An extension can also be assigned to ring the maintenance modem. Each RDDU can be
set for either wink start or immediate. All RDDU lines support DNIS and ANI features.
RDDU controls, indicators, and interface connectors are shown in
Figure 4-18
and described in
Table 4-10
.
RDDU Installation
Note
Switches are factory-set to the 0 (0 dB signal level drop) position.
1. If the KSU is located within one mile of the PBX or CO, set dB Pad switches SW101 through
SW401 to the 3 (-3 dB signal level drop) position to control excessive loudness resulting from
close proximity to the PBX or CO.
2. Sensitivity jumpers P101~P401 are used mostly for dial pulse operation, to adjust for dial
pulsing at different loop lengths. If close to the central office, the sensitivity should be set for
low (L); as the loop length increases, it should be set to medium (M), then high (H).
3. Insert the RDDU (component side facing right) into the appropriate slot and apply firm, even
pressure to ensure proper mating of connectors.
4. After installing the RDDU, gently pull the PCB outward. If the connectors are properly mated,
a slight resistance is felt.
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...