Strata CTX Configuration
Worksheet 7 – System Power Factor Check
Strata CTX I&M 10/02
1-43
Str
a
ta CT
X
C
o
nfigu
ration
Telephone/Device Power Factors
The power supply of each cabinet supplies a limited amount of power. Use the Worksheet below to
calculate the total Telephone/Device -24 VDC PF for each cabinet. Add it to the appropriate
cabinet in
“Cabinet Power Factor Check” on page 1-44
. Telephones do not have +5VDC PFs.
Note
PF varies by number of telephones because of station paging limit of 32 telephones. Always
use “1.0” for DKT telephones when calculating PFs for individual cabinets.
Main Location _______________ Remote Location 1___ 2___ 3___ 4____ 5___ 6____
Telephone/Device
Cabinet 1 (Base)
Cabinet 2 (Exp.)
Cabinet 3 (Exp.)
Cabinet 4 (Exp.)
Qty.
-24 VDC
PF
Total
Qty.
-24 VDC
PF
Total
Qty.
-24 VDC
PF
Total
Qty.
-24 VDC
PF
Total
DKT (any series)
x 1.0 =
x 1.0 =
x 1.0 =
x 1.0 =
DDCB (with
MDFB)
x 1.2 =
x 1.2 =
x 1.2 =
x 1.2 =
DDSS Console
x 0.8 =
x 0.8 =
x 0.8 =
x 0.8 =
Add-on Module
(DADM)
x 0.4 =
x 0.4 =
x 0.4 =
x 0.4 =
BATI
x 0.7 =
x 0.7 =
x 0.7 =
x 0.7 =
Integrated BPCI
(future)
x 0.2 =
x 0.2 =
x 0.2 =
x 0.2 =
Standard Phone
(-48VDC)
x 1.0 =
x 1.0 =
x 1.0 =
x 1.0 =
Standard Phone
(-24VDC)
x 0.5 =
x 0.5 =
x 0.5 =
x 0.5 =
Power Failure Unit
(DPFT)
x 3.0 =
x 3.0 =
x 3.0 =
x 3.0 =
HHEU or BHEU
x 0.1 =
x 0.1 =
x 0.1 =
x 0.1 =
BVSU or DVSU
x 0.2 =
x 0.2 =
x 0.2 =
x 0.2 =
Total Power Factor
(PF)
Telephone PF ____
Telephone PF ____
Telephone PF ____
Telephone PF ____
Telephone/Device
Cabinet 5 (Exp.)
Cabinet 6 (Exp.)
Cabinet 7 (Exp.)
Qty.
-24 VDC
PF
Total
Qty.
-24 VDC
PF
Total
Qty.
-24 VDC
PF
Total
DKT (any series)
x 1.0 =
x 1.0 =
x 1.0 =
DDCB (w.MDFB)
x 1.2 =
x 1.2 =
x 1.2 =
DDSS Console
x 0.8 =
x 0.8 =
x 0.8 =
Add-on Module
x 0.4 =
x 0.4 =
x 0.4 =
BATI
x 0.7 =
x 0.7 =
x 0.7 =
Integrated BPCI (future)
x 0.2 =
x 0.2 =
x 0.2 =
Standard Telephone (-48VDC)
x 1.0 =
x 1.0 =
x 1.0 =
Standard Telephone (-24VDC)
x 0.5 =
x 0.5 =
x 0.5 =
Power Failure Unit (DPFT)
x 3.0 =
x 3.0 =
x 3.0 =
HHEU or BHEU
x 0.1 =
x 0.1 =
x 0.1 =
BVSU or DVSU
x 0.2 =
x 0.2 =
x 0.2 =
Total Power Factor (PF)
Telephone PF ____
Telephone PF ____
Telephone PF ____
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...