PCB Installation
BIOU – Option Interface Units
4-6
Strata CTX I&M 10/02
BIOU – Option Interface Units
Circuits per PCB:
(see interfaces)
Interfaces with:
three music-on-hold sources, system page and control relays
Older Version(s):
none
The BIOU provides a Paging Output (amplified and non-amplified), four zone paging relays, three
Music-on-hold (MOH) interfaces and four control relays (Night Transfer, Night Bell and
Background Music (BGM) mute). One or two BIOUS can be installed in a Strata CTX.
BIOU controls, indicators, and interface connectors are shown in
Figure 4-3
and described in
Table 4-2.
BIOU Installation
➤
Insert the BIOU (component side facing right) into any available PCB slot in the cabinet. See
“Worksheet 6: Strata CTX670 Cabinet Slot Configuration” on page 1-36
. Apply firm, even
pressure to ensure proper mating of connectors.
Figure 4-3
BIOU PCB
5805
BIOU1A
600/600
600/600
600/600
600/600
B
B
B
B N.C
M M M M N.O
Mu
A
SW1
SW600
MOH3
MOH2
MOH1
SP
SP0
SP1
MOH3
MOH2
MOH1
SP
SW600
SP0
SP1
B
B
B
B N.C
M M M M N.O
Mu
A
SW1
J3
J2
J1
SW100
Control Relay
Jumpers
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...