Strata CTX Configuration
CTX100 Maximum Capacity Configuration Examples
1-34
Strata CTX I&M 10/02
CTX100: Analog Tie, DID and/or Ground Start Lines
Table 1-42
CTX100 Base: 16 stations, 12 Tie, DID and/or Ground Start Lines
S101
S102
S103
S104
BDKU/
BDKS
RxxU
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start
lines.
RxxU
16 DKTs
4 lines
4 lines
4 lines
Table 1-43
CTX100 Base: 0 stations, 16 Tie, DID and/or Ground Start Lines
S101
S102
S103
S104
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start
lines.
RxxU
RxxU
RxxU
4 lines
4 lines
4 lines
4 lines
Table 1-44
CTX100 Base and Expansion Cabinet with Analog Tie, DID and/or Ground Start
Lines
8 Universal Slots
72 Stations (Max.)
32 CO lines (Max.)
80 St Analog Tie, DID and/or ground start Lines combined
(Max.)
Table No.
Stations
Analog Tie, DID, and/or Ground Start Lines
1-45
72
12 lines (4 Tie/DID max.)
1-46
64
16 lines (8 Tie/DID max.)
1-47
56
16 lines (12 Tie/DID max.)
1-48
48
16 lines any type
1-49
48
20 lines (16 Tie/DID max.)
1-50
32
24 lines any type
1-51
16
28 lines any type
Table 1-45
CTX100 Base & Expansion: 72 stations, 4 Tie or DID and 8 Ground Start Lines
S101
S102
S103
S104
S105
S106
S107
S108
BDKU/
BDKS
BDKU/
BDKS
ADKU
RGLU
2
BDKU/
BDKS
BDKU/
BDKS
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.
RGLU
2
2. RGLU can not be substituted with REMU or RDDU because of cabinet power factor.
16 DKTs
16 DKTs
8 DKTs
4 lines
16 DKTs
16 DKTs
4 lines
4 lines
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...