MDF PCB W
irin
g
MDF PCB Wiring
Station Wiring Diagrams
Strata CTX I&M 10/02
PRELIMINARY & CONFIDENTIAL
7-5
ADKU and BDKU/BDKS Digital Station Wiring
Figure 7-2
ADKU and BDKU/BDKS (DKT, DDCB, ADM, DDS, BATI, BDIU-DI) Wiring
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
W-BL
BL-W
W-O
O-W
W-GN
GN-W
W-BR
BR-W
W-S
S-W
R-BL
BL-R
R-O
O-R
R-GN
GN-R
R-BR
BR-R
R-S
S-R
BK-BL
BL-BK
BK-O
O-BK
BK-GN
GN-BK
BK-BR
BR-BK
BK-S
S-BK
Y-BL
BL-Y
Y-O
O-Y
Y-GN
GN-Y
Y-BR
BR-Y
Y-S
S-Y
V-BL
BL-V
V-O
O-V
V-GN
GN-V
V-BR
BR-V
V-S
S-V
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
37
12
38
13
39
14
40
15
41
16
42
17
43
18
44
19
45
20
46
21
47
22
48
23
49
24
50
25
Bridging
Clips
To ADKU or BDKU/BDKS
W/Female Connector
66M150 Split Block
Circuit 2
Circuit 3
ADKU
or
BDKU
BDKS
Circuit 4
Circuit 6
Circuit 7
Circuit 8
Circuit 10
Circuit 11
Circuit 12
Circuit 13
Circuit 14
Circuit 15
Circuit 16
Circuit 5
(-) T1 (Voice/Data)
(GND) R1 (Voice/Data)
(-) PT1 (Add. Power)
(GND) PR1 (Add. Power)
T2
R2
PT2
PR2
T3
R3
PT3
PR3
T4
R4
PT4
PR4
T5
R5
PT5
PR5
T6
R6
PT6
PR6
T7
R7
PT7
PR7
T8
R8
PT8
PR8
T10
R10
T11
R11
T12
R12
T13
R13
T14
R14
T15
R15
T16
R16
Not Used
Jacketed Twisted Pairs
24 AWG (1 or 2 pair. See Note 1.)
Station Cabling
GN
6 5 4 3 2 1
Y
BL
R
BK
W
3 4
R1
PT1
T1
PR1
2
5
PR TR PT
RJ11
Digital Telephone (with or
w/o ADM, BDIU-DI), DSS,
BATI or DDCB.
RPCI and PDIU-DI are not
supported.
Digital Telephone (with or
w/o ADM, BDIU-DI), DSS,
BATI or DDCB.
RPCI and PDIU-DI are not
supported.
Modular
Cord
GND
PR
(-)
T
GND
R
(-)
PT
(-) T9 (Voice/Data
(GND) R9 (Voice/Data)
Jacketed Twisted Pairs 24 AWG
GN
6 5 4 3 2 1
Y
BL
R
BK
W
3 4
R1
T1
RJ11
Modular
Cord
5501
(-)
T
GND
R
Notes
1. T/R wires are always required; PT/PR are additional power wires
required only for long station runs per
Table 7-1
. PT/PR may be used
with normal station runs also.
2. Voltage levels:
T, PT = -26.3~27.8 VDC
R, PR = 0.0 VDC (GND). Reference to SG ground.
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...