Strata CTX Configuration
CTX100 Maximum Capacity Configuration Examples
Strata CTX I&M 10/02
1-35
Str
a
ta CT
X
C
o
nfigu
ration
Table 1-46
CTX100 Base & Expansion: 64 stations, 8 tie or DID and 8 Ground Start Lines
S101
S102
S103
S104
S105
S106
S107
S108
BDKU/
BDKS
BDKU/
BDKS
RxxU
RGLU
2
BDKU/
BDKS
BDKU/
BDKS
RxxU
1
RGLU
2
16 DKTs
16 DKTs
4 lines
4 lines
16 DKTs
16 DKTs
4 lines
4 lines
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.
2. RGLU can not be substituted with REMU or RDDU because of cabinet power factor.
Table 1-47
CTX100 Base & Expansion: 56 stations, 12 Tie or DID and 4 Ground Start Lines
S101
S102
S103
S104
S105
S106
S107
S108
BDKU/
BDKS
ADKU
RxxU
RxxU
BDKU/
BDKS
BDKU/
BDKS
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.
RGLU
2
2. RGLU can not be substituted with REMU or RDDU because of cabinet power factor.
16 DKTs
8 DKTs
4 lines
4 lines
16 DKTs
16 DKTs
4 lines
4 lines
Table 1-48
CTX100 Base & Expansion: 48 stations, 16 Tie, DID and/or Ground Start Lines
S101
S102
S103
S104
S105
S106
S107
S108
BDKU/
BDKS
ADKU
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.
RxxU
BDKU/
BDKS
ADKU
RxxU
RxxU
16 DKTs
8 DKTs
4 lines
4 lines
16 DKTs
8 DKTs
4 lines
4 lines
Table 1-49
CTX100 Base & Expansion: 48 stations, 16 Tie or DID and 4 Ground Start Lines
S101
S102
S103
S104
S105
S106
S107
S108
BDKU/
BDKS
BDKU/
BDKS
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.
RGLU
2
2. RGLU can not be substituted with REMU or RDDU because of cabinet power factor.
BDKU/
BDKS
RxxU
RxxU
RxxU
16 DKTs
16 DKTs
4 lines
4 lines
16 DKTs
4 lines
4 lines
4 lines
Table 1-50
CTX100 Base & Expansion: 32 stations, 24 Tie, DID and/or Ground Start Lines
S101
S102
S103
S104
S105
S106
S107
S108
BDKU/
BDKS
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.
RxxU
RxxU
BDKU/
BDKS
RxxU
RxxU
RxxU
16 DKTs
4 lines
4 lines
4 lines
16 DKTs
4 lines
4 lines
4 lines
Table 1-51
CTX100 Base & Expansion: 16 stations, 28 lines
S101
S102
S103
S104
S105
S106
S107
S108
BDKU/
BDKS
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.
RxxU
RxxU
RxxU
RxxU
RxxU
RxxU
16 DKTs
4 lines
4 lines
4 lines
4 lines
4 lines
4 lines
4 lines
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...