9
This chapter provides information and diagrams for connecting peripheral equipment to the Strata
CTX interface circuits. These interfaces include those listed below:
•
Application PC and Server Interfaces
•
Strata CTX WinAdmin, ACD, Attendant Console, SMDI and SMDR
•
Music-On-Hold/Background Music Interfaces
•
External Page with BIOU Interface
•
Control Relays with BIOU Interface
•
Door Phone/Door Lock with DDCB Interface
•
Telephone External Ringer with HESB Interface
•
Amplified Page with HESB Interface
•
Amplified Page/Talk-Back with HESB Interface
•
Power Failure Cut-through with DPFT Interface
•
Station Message Detailed Recording
Application PC and Server Interfaces
Application PCs and/or servers are connected to the Strata CTX system via a Network Interface
jack, RS-232 serial ports and/or a Strata CTX modem depending on the application. These
interfaces are provided by the CTX system processor. The network jack and built-in modem are
standard equipment on the CTX670 processor and option PCBs on the CTX100 processor. The
BSIS four-port serial interface is an optional PCB that mounts on the CTX100 or CTX670
processor (see
Figure 9-1
).
•
CTX WinAdmin, Stratagy VM Proprietary Integration, Attendant Console and ACD
Network Interface – These application PC/servers equipped with a standard Network
Interface Card (NIC) connect to the Strata CTX network jack. One network interface jack is
standard on the Strata CTX670, BBCB processor PCB. The AETS option is required on the
CTX100 ACTU processor. This is the only network jack interface on the Strata CTX (see
Figures 9-1
~
9-4
).
Note
Attendant Console and ACD are in future releases.
•
CTX WinAdmin Modem Interface – CTX WinAdmin PC servers equipped with a modem
can connect the Strata CTX maintenance modem. One built-in maintenance Modem is standard
on the Strata CTX670, BECU processor PCB. An AMDS option PCB is required for CTX100
ACTU processor PCB.The Strata CTX modem supports point-to-point TCP/IP connection to a
CTX WinAdmin PC modem over PSTN telephone lines (see
Figure 9-5
for a connection
diagrams).
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...