Strata CTX Configuration
System Capacities
1-10
Strata CTX I&M 10/02
Door locks
4
5
10
Door phone control boxes (DDCB)
2
3
8
Door phones
6
9
24
DSS consoles (DDSS)
3
5
16
ISDN BRI station circuits TE-1 and TA
(2B+D per circuit)
12
28
96
Off-premise stations
72
160
560
BPCI (future) used for TAPI only: per
cabinet
1
35
66
66
Total Stations (Digital/Analog/ISDN BRI B
channel combined)
72
160
560
Standard stations
64
160
560
Calls existing at the same time
56
96
366
1. Limit is based on cabinet Power Factor (PF).
Table 1-5
Line Capacities and Universal PCB Slots
Lines
CTX100
Base & Expansion
CTX670
Basic
Processor
BBCU + BECU
CTX670
Expanded
Processor
BBCU + BECU +
BEXS + BBMS
CO lines – loop start
(analog - 8 lines/slot)
64
96
264
CO lines – ground start
(analog - 4 lines/slot)
32
72
264
DID lines (analog - 4 lines/slot)
32
72
264
Tie lines (analog - 4 lines/slot)
32
72
264
VoIP lines (4 lines/slot)
1
1. Capacity is limited by FCC, Part 15, ElectroMagnetic Compatibility (EMC) restrictions.
8
20
20
T1 lines (DS-1)
2
2. T1 lines can be loop start, ground start, Tie or DID (maximum 24 lines per unit, any type or combination).
64
96
264
ISDN BRI B channel lines
3
3. BRI lines provide CO line services, including Caller ID, DID and Direct Inward Lines (DIL).
64
96
256
ISDN PRI B channel lines
4
4. PRI lines provide CO line services, including QSIG Networking, Calling Party Number/Name, DID, Tie, POTS, FX and DIT.
48
96
264
Total lines (Analog, T1, ISDN BRI and
PRI B channels combined)
64
96
264
Channel Groups
32
48
128
Number of groups with Group CO Line
buttons
32
50
128
Table 1-4
Station/Peripherals System Capacities (continued)
Stations
CTX100
Base & Expansion
CTX670
Basic Processor
BBCU + BECU
CTX670
Expanded Processor
BBCU + BECU +
BEXS + BBMS
Summary of Contents for Strata CTX100
Page 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Page 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Page 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Page 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Page 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Page 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Page 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...