421
6
F
2
S
0
8
5
0
COM1 COM2 COM3 COM4
COM5
SA SA SSA
85S1
Fixed
bit
85S2
SUB2
COM
R
D
Y
S
A
S
P
1
SUB3
COM
RA2
Frame
header
1 Ia 1 Ia Ib 1 Ib 1
Ic 1 Ic V1 1 Io
87
SA/
SSA
8
5
S
1
1
8
5
S
2
R
A
1
R
D
Y
S
A
S
P
R
A
2
C
R
C
1 CRC 1 CRC
10
bits 8 1
4 4
1 8 1
8 1 4 4
1 4 3 1 1 1 1 1 1
1
1
2
1 8 1
6
88 bits
Frame
No.
V1 Io
SUB2-COM
∗
CBDS / RA
SA
SUB-COM
∗
SP1
SUB3_COM
∗
RA2
V.COM1
V.COM2
V.COM3 S.V.COM
∗
I.COM1
I.COM2
I.COM3
S.I.COM
∗
∗
∗
∗
0
1
V1 / SPARE
1
Io / SPARE
1
RA0 / CBDS-A
0
2
0
, 2
8
1 RA3
/
SPARE
1
2
V1 / SPARE
2
Io / SPARE
2
RA1 / CBDS-B
0
2
1
, 2
9
2 RA4
/
SPARE
2
3
V1 / SPARE
3
Io / SPARE
3
RA2 / CBDS-C
0
2
2
, 2
10
3 RA5
/
SPARE
3
4
V1 / SPARE
4
Io / SPARE
4
RA0 / CBDS-A
0
2
3
, 2
11
4 RA3
/
SPARE
4
V1 /
V1 /
V1 /
5
V1 / SPARE
Io /
Io /
Io /
5
Io / SPARE
5
RA1 / CBDS-B
1
SP flag
5
RA4 / SPARE
5
SPARE
SPARE
SPARE
6
V1 / SPARE
SPARE
SPARE
SPARE
6
Io / SPARE
6
RA2 / CBDS-C
1
ARC BLOCK
2
4
, 2
12
6 RA5
/
SPARE
6
7
V1 / SPARE
7
Io / SPARE
7
RA0 / CBDS-A
2
Local test
2
5
, 2
13
7 RA3
/
SPARE
7
8
V1 / SPARE
8
Io / SPARE
8
RA1 / CBDS-B
3
0
2
6
, 2
14
8 RA4
/
SPARE
8
9
V1 / SPARE
9
Io / SPARE
9
RA2 / CBDS-C
1
2
7
, 2
15
9 RA5
/
SPARE
9
10
V1 / SPARE
10
Io / SPARE
10
RA0 / CBDS-A
5
-
10
RA3 / SPARE
10
11
V1 / SPARE
11
Io / SPARE
11
RA1 / CBDS-B
4
-
11
RA1 / SPARE
11
12
V1 / SPARE
12
Io / SPARE
12
RA2 / CBDS-C
S.F.C.
-
12
RA2 / SPARE
Legend
Ia, Ib, Ic :
Phase current
V1 :
Positive-sequence voltage
Io :
Zero-sequence current
ON / OFF : Control data
RDY :
Ready
SA :
Sampling address for a cycle
SSA
Sampling address for a second
SP :
Sampling synchronization
CRC :
Cyclic redundancy check
S.F.C. Simultaneous
fault
control
(synchronized test trigger signal)
Next
Frame
Time
data(*)
(*) Time data are transmitted once per two cycle.
(1)
(2)
(3)
(4)
(5)
Figure N-2 Data Transmission Format of B-MODE and GPS-MODE
User configurable commands are as:
COM1 to COM3:
Used for sampling address.
COM4 and COM5: Used for transfer signals.
SUB_COM:
These commands are sent every 12 frames. SUB_COM1 and SUB_COM2
are assigned to ARC_BLOCK and Local test signals as default setting. If
these signals are changed, the related functions cannot be applied.
V.COM1 to V.COM3 and S.V.COM1 to S.V.COM12: If the OST and FL functions are not used,
the user can use these commands. The V.COM1 to V.COM3 commands
are sent every frame. The S.V.COM1 to S.V.COM12 are sent every 12
frames.
I.COM1 to I.COM3 and S.I.COM1 to S.I.COM12: If the DIFG function is not used, the user can
use these commands. The I.COM1 to I.COM3 commands are sent every
frame. The S.I.COM1 to S.I.COM12 are sent every 12 frames.
www
. ElectricalPartManuals
. com
Summary of Contents for GRL100-701B
Page 329: ... 328 6 F 2 S 0 8 5 0 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Page 339: ... 338 6 F 2 S 0 8 5 0 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Page 351: ... 350 6 F 2 S 0 8 5 0 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Page 381: ... 380 6 F 2 S 0 8 5 0 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Page 413: ... 412 6 F 2 S 0 8 5 0 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Page 417: ... 416 6 F 2 S 0 8 5 0 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Page 453: ... 452 6 F 2 S 0 8 5 0 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Page 457: ... 456 6 F 2 S 0 8 5 0 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Page 473: ...w w w E l e c t r i c a l P a r t M a n u a l s c o m ...