196
G7 ASD Operation Manual
Note:
Input and Output power wires require shielding for CE compliance.
Note:
(*) Indicates that the item is one of a set of two parallel cables.
Note:
(**) Indicates that a 1.5” conduit orifice is required if using the recommended cable
size.
Table 19. 460-volt G7 ASD Cable/Terminal Specifications.
Model
VT130G7U
MCP
Rating
(Amps)
Typical Wire/Cable Size (AWG or kcmil)
Lug Size Range
Input/Output Power
AM, FM, and II
Terminals
Control Terminals
Wire-Size/Lug-Capacity for
Input/Output Power
Recommended
Maximum
4015B
15
14
10
20
(3-core shield)
18
(2-core shield)
24 to 8
4025B
15
14
10
4035B
15
14
10
4055B
15
14
10
4080B
20
14
10
4110B
30
12
10
4160B
30
10
4
18 to 4
4220B
50
8
4
4270B
75
8
4
4330B
75
6
4
4400B
100
4
4
4500B
100
3
2
16 to 1
4600B
125
2
2
10 to 1/0
4750B
175
1
**2
410KB
200
2/0
2/0
12 to 4/0
412KB
250
*1/0
*4/0
*(6 to 250)
415KB
300
*2/0
*4/0
420KB
400
*4/0
*500
*(1/0 to 500)
425KB
500
*300
*500
430KB
600
*400
*500
435KB
700
*500
*500