G7 ASD Operation Manual
117
Drooping Reference
Program
⇒
Feedback Parameters
⇒
Drooping Control
⇒
Drooping
Reference
This parameter sets the method to be used in determining the output torque
while operating in the Drooping Control mode.
Settings:
Total Torque Calculated by the Detection Current.
Torque without Acc/Dec Torque Calculated by Detection Current.
Total Torque Calculated by the Command Current.
Torque without Acc/Dec Torque Calculated by the Command Current.
Direct Access Number — F327
Parameter Type — Selection List
Factory Default — Total torque
calculated by the detection current
Changeable During Run — Yes
Light-load High-speed Operation Selection
Program
⇒
Special Control Parameters
⇒
Crane/Hoist Settings
⇒
Express Speed Settings
⇒
Light-Load High-Speed Operation
This parameter enables the Light-Load High-Speed function by selecting an
operating mode. The Light-Load High-Speed function accelerates the output
frequency of the ASD from the programmed speed to the setting established in
F341
.
This parameter may be disabled.
If either of the other selections are made and configured,
and after the
criteria of
F331
–
F333
are met, the Light-Load High-Speed function is
enabled and this parameter determines the operating mode of the Light-Load
High-Speed function.
Settings:
Disabled
Reserved
Automatic Enable - Automatic Speed (
F341
)
Automatic Enable - Preset Speed (Preset ID
Bin
is OR’ed w/1000
Bin
)
Discrete Enable - Automatic Speed (
F341
) (see item 60 of
Table 8 on pg. 76
)
Discrete Enable - Preset Speed (Preset ID
Bin
is OR’ed w/1000
Bin
) (see item
60 of
Table 8 on pg. 76
)
Direct Access Number — F330
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
Minimum — 30.0
Maximum — Upper Limit (
F012
)
Units — Hz
Light-Load High-Speed Operation Switching Lower-Limit
Frequency
Program
⇒
Special Control Parameters
⇒
Crane/Hoist Settings
⇒
Express Speed Settings
⇒
Light-Load High-Speed Operation
Switching Lower-Limit Frequency
This parameter sets an output frequency threshold that, once surpassed, allows
the Light-load High-speed function to be used.
The Light-Load High-Speed function may be used if the frequency threshold
(
F331
) and the following conditions are met:
1) Light-Load High-Speed Operation Enable is configured at
F330
.
2) The output torque is less than the setting established in
F335
when reaching
the frequency setting here.
Direct Access Number — F331
Parameter Type — Numerical
Factory Default — 40.00
Changeable During Run — Yes
Minimum — 30.0
Maximum — Upper Limit (F012)
Units — Hz
F327