194
G7 ASD Operation Manual
Table 17. 600 Volt NEMA Type-1/IP-20 Chassis standard ratings table.
4270B
27.0
25.0/18.5
380 – 480 VAC
(±10%)
Input Voltage Level
(Max.)
38.0/41.8 A
57.0 A
4330B
33.0
30.0/22.0
45.0/49.5 A
67.5 A
4400B
40.0
40.0/30.0
57.0/62.7 A
85.5 A
4500B
50.0
50.0/37.0
71.0/78.1 A
106.5 A
* 4600B
60.0
60.0/45.0
83.0/91.3 A
124.5 A
* 4750B
75.0
75.0/55.0
104.0/114.4 A
156.0 A
* 410KB
100
100/75.0
138.0/151.8 A
207.0 A
* 412KB
125
125/90.0
172.0/189.2 A
258.0 A
N/A
* 415KB
150
150/110
206.0/226.6 A
309.0 A
* 420KB
200
200/150
275.0/302.5 A
412.5 A
* 425KB
250
250/185
343.0/377.3 A
514.5 A
* 430KB
300
300/220
415.0/456.5 A
622.5 A
* 435KB
350
350/243
447.0/491.7 A
586.8 A
670.5 A
Note:
*12-Pulse option available.
Model
VT130G7U
Rated
KVA
Motor
HP/Kw
Input Voltage
3-Ph 50/60
±2 Hz
Output Voltage
3-Ph Variable
Frequency
Output
Current 100/
110% Cont.
Overload
Current 150%
for 60 Secs.
Overload
Current 150%
for 120 Secs.
6015B
1.5
1.0/0.75
495 – 600 VAC
(+5/-10%)
Input Voltage Level
(Max.)
2.1/2.3 A
N/A
3.2 A
6025B
2.5
2.0/1.5
3.0/3.3 A
4.5 A
6035B
3.5
3.0/2.2
4.0/4.4 A
6.0 A
6060B
6.0
5.0/3.7
6.1/6.7 A
9.2 A
6080B
8.0
7.5/5.0
9.0/9.9 A
13.5 A
6110B
11.0
10.0/7.5
12.0/13.2 A
18.0 A
6160B
16.0
15.0/11.2
17.0/18.7 A
25.5 A
6220B
22.0
20.0/14.9
495 – 600 VAC
(±10%)
22.0/24.2 A
33.0 A
6270B
27.0
25.0/18.5
27.0/29.7 A
40.5 A
6330B
33.0
30.0/22.0
32.0/35.2 A
48.0 A
6400B
40.0
40.0/30.0
41.0/45.1 A
61.5 A
6500B
50.0
50.0/37.0
52.0/57.2 A
78.0 A
6600B
60.0
60.0/45.0
62.0/68.2 A
93.0 A
6750B
75.0
75.0/55.0
77.0/84.7 A
115.5 A
* 610KB
100
100/75.0
99.0/108.9 A
148.5 A
* 612KB
125
125/90.0
125.0/137.5 A
187.5 A
N/A
* 615KB
150
150/110
150.0/165.0 A
225.0 A
* 620KB
200
200/150
200.0/220.0 A
300.0 A
* 625KB
250
250/185
250.0/275.0 A
375.0 A
* 630KB
300
300/224
289.0/317.9 A
433.5 A
Note:
*12-Pulse option available.
Table 16. (Continued) 460 Volt NEMA Type-1/IP-20 Chassis standard ratings table.
Model
VT130G7U
Rated
KVA
Motor
HP/Kw
Input Voltage
3-Ph 50/60
± 2 Hz
Output Voltage
3-Ph Variable
Frequency
Output
Current 100/
110% Cont.
Overload
Current
130% for
120 Secs.
Overload
Current
150% for
60 Secs.
Overload
Current
150% for
120 Secs.