G7 ASD Operation Manual
191
EOI Installation Precautions
Install the unit securely in a well ventilated area that is out of direct sunlight using the four mounting holes
of the EOI. The ambient temperature rating for the EOI is 14 to 104° F (-10 to 40° C).
•
Select a mounting location that is easily accessible by the user.
•
Avoid installation in areas where vibration, heat, humidity, dust, metal particles, or high levels of
electrical noise (EMI) are present.
•
Do not install the EOI where it may be exposed to flammable chemicals or gases, water, solvents, or
other fluids.
•
Turn the power on only after securing the front cover to the ASD.
EOI Remote Mounting w/o the ASD-MTG-KIT
Note:
See
Figure 29
for the dimensions and the item locations referenced in steps
1
through
5
.
1.
At the EOI mounting location, identify and mark the location of the 3.80” by 3.29” hole and the
7/32” screw holes.
2.
Cut the 3.80” by 3.29” rectangular hole.
3.
Drill the four 7/32” screw holes.
4.
Attach and secure the EOI to the front side of the mounting location using the four 6-32 x 5/16” pan
head screws, the #6 split lock washers, and the #6 flat washers.
5.
Connect the RJ-45 extension cable(s).
EOI Dimensions (mounting)
Figure 29. EOI Mounting Dimensions.