62
G7 ASD Operation Manual
Type Reset
Program
⇒
Utility Parameters
⇒
Type Reset
This feature assists the user when performing fault analysis or by
allowing a quick system setup change when required. Performing a
Type Reset results in one of the following user-selected post-reset
configurations.
Settings:
None
Auto Setup for 50 Hz
Auto Setup for 60 Hz
Restore Factory Defaults
Clear Trip
Clear Run Timer
New Base Drive Board
*Save User Parameters
Restore User Parameters
Reload EOI Flash
Reset EOI Memory
Note:
*User settings that are stored in the memory of the EOI are not
saved via the Save User Parameters selection. The unsaved
functions include the EOI Option Setups, (Utility Parameters
⇒
)
Display Units, and (Monitor Setup
⇒
) Scrolling Monitor
Select.
Direct Access Number — F007
Parameter Type — Selection List
Factory Default — None
Changeable During Run — No
Direction (of motor rotation)
No path available (Direct Access Only)
While operating using the LED Keypad Option this parameter sets the
direction of motor rotation. This setting may be changed during operation. This
setting will not override parameter
F311
(Forward/Reverse Disable).
If either direction is disabled via parameter
F311
, the disabled direction will not
be recognized if commanded by the LED Keypad. If both directions are
disabled via parameter
F311
, the direction command from the LED Keypad
will determine the direction of the motor rotation.
Settings:
Forward
Reverse
Note:
If using the LCD EOI, press ESC from the Frequency
Command screen to access the Motor Direction parameter.
Direct Access Number — F008
Parameter Type — Selection List
Factory Default — Forward
Changeable During Run — Yes
Reset
F007