8.4
Troubleshooting for the Image
8.4.1
Abnormality of image density / Gray balance
Fig.8-3
Defective area
Step
Check items
Prescription
Density/Gray balance
1
Check the density/gray balance.
Adjust the density.
Printer section
2
Check test print image (04-114).
Go to step 4 if there is any problem
on image.
Scanner
3
Are the original glass and CIS unit
dirty?
Clean them.
Printed image
4
Is the image faded?
Perform troubleshooting for faded
image.
5
Is background fogging occurring?
Perform troubleshooting for
background fogging.
6
Is there a blotch on the image?
Perform troubleshooting for blotched
image.
7
Is the image transferred normally?
Perform troubleshooting for
abnormal transfer.
Feeding direction
Image density