05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
20L/
23L/
25L
20H/
23H/
25H
08
Setting
mode
Process
Development Toner near empty
5155
-
Toner near empty
threshold setting
1
0-3
M
Sets the timing for when the toner near empty display
appears. The larger the value, the later the display appears.
0: Longer *1
1: Center
2: Shorter *2
3: No detection
*1: The period of time (number of counts) from the
appearance of the near empty display to actually running
out of toner is longer (larger) than that of "center".
*2: The period of time (number of counts) from the
appearance of the near empty display to actually running
out of toner is shorter (smaller) than that of "center".
1
Y
Y
08
Setting
mode
Process
Development Toner near empty
5156
3
Fine adjustment
ofthreshold
fordisplaying
remainingtoner and
toner nearempty
100
50-150
M
Adjusts the threshold value for displaying remaining amount
of toner and toner near empty. Display threshold value =
default threshold value x setting value/100 (unit: %)
50: Setting value x 0.5
100: Setting value x 1.0
150: Setting value x 1.5
4
Y
Y
08
Setting
mode
Process
Fuser
Fusing correction
control time
immediately after
warming-up
5210
0
Temperature correction
2
0-10
M
0: Disable 1: 1 min. 2: 2 min. 3: 3 min. 4: 4 min. 5: 5 min. 6:
6 min. 7: 7 min. 8: 8 min. 9: 10 min. 10: 15 min.
4
Y
Y
08
Setting
mode
Process
Fuser
Fusing correction
control time
immediately after
warming-up
5210
1
Maximum time of lamp
ON
2
0-10
M
0: Disable 1: 1 min. 2: 2 min. 3: 3 min. 4: 4 min. 5: 5 min. 6:
6 min. 7: 7 min. 8: 8 min. 9: 10 min. 10: 15 min.
4
Y
Y
08
Setting
mode
Process
Fuser
Correction of
temperature rising
prevention (Latest
value)
5337
0
Ready
0
0-15
M
0: 0
o
C 1: -1
o
C 2: -2
o
C 3: -3
o
C 4: -4
o
C 5: -5
o
C 6: -6
o
C 7:
-7
o
C 8: -8
o
C 9: -9
o
C 10: -10
o
C 11: -11
o
C 12: -12
o
C 13: -
13
o
C 14: -14
o
C 15: -15
o
C
14
Y
Y
08
Setting
mode
Process
Fuser
Correction of
temperature rising
prevention (Latest
value)
5337
1
Printing
0
0-15
M
0: 0
o
C 1: -1
o
C 2: -2
o
C 3: -3
o
C 4: -4
o
C 5: -5
o
C 6: -6
o
C 7:
-7
o
C 8: -8
o
C 9: -9
o
C 10: -10
o
C 11: -11
o
C 12: -12
o
C 13: -
13
o
C 14: -14
o
C 15: -15
o
C
14
Y
Y
08
Setting
mode
Process
Fuser
5469
-
Low power
consumption control
0
0-1
M
This code is used when using low power consumption
control. Note that inconsistent fusing may occur if the fuser
roller temperature is low. Use the above default value,
unless otherwise required.
0: Invalid, 1: Valid
1
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-1-61
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)