05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptabl
e value
SRAM
Contents
Proce
dure
20L /
23L /
25L
20H /
23H /
25H
05
Adjustment
mode
Scanner
Scanner
3047
-
Carriage position
adjustment during
scanning from RADF
(color)
128
0-255
M
1
Y
Y
05
Adjustment
mode
Scanner
RADF
3050
-
Adjustment of the
RADF tray volume
(minimum)
20
0-255
M
This is used for improving the detection accuracy of the
width of the original set on the original tray. The condition of
the sensor when the tray width is minimized is memorized.
The appropriate range of the adjustment value is between 0
and 100.
6
Y
Y
05
Adjustment
mode
Scanner
RADF
3051
-
Adjustment of the
RADF tray volume
(maximum)
220
0-255
M
This is used for improving the detection accuracy of the
width of the original set on the original tray. The condition of
the sensor when the tray width is maximized is memorized.
The appropriate range of the adjustment value is between
200 and 255.
6
Y
Y
05
Adjustment
mode
Scanner
RADF
3052
-
Adjust ment for DF
trailing edge tolerance
(black)
115
0-255
M
1
Y
Y
05
Adjustment
mode
Scanner
RADF
3053
-
Adjust ment for DF
trailing edge tolerance
(Color 600 dpi)
128
0-255
M
1
Y
Y
05
Adjustment
mode
Scanner
RADF
3054
-
Adjust ment for DF
trailing edge tolerance
(Color 300 dpi)
132
0-255
M
1
Y
Y
05
Adjustment
mode
Scanner
Scanner
LED
3219
-
Light volume
adjustment
(color/black)
-
-
M
Light volume adjustment of LED is performed.
Adjustment for color scans is performed after the
adjustment for a black scan.
6
Y
Y
05
Adjustment
mode
Scanner
Scanner
LED
3220
-
Light volume
adjustment (black)
-
-
M
Light volume adjustment of LED is performed. Only
adjustment for black scans is performed.
6
Y
Y
05
Adjustment
mode
Scanner
Scanner
LED
3221
-
Light volume
adjustment (color)
-
-
M
Light volume adjustment of LED is performed.
Only adjustment for color scans is performed.
6
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-1-7
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)