05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
23LA
23LM/
28LM
23HA/
28HA
08
Setting
mode
Process
Development Toner near empty
5156
3
Fine adjustment
ofthreshold
fordisplaying
remainingtoner and
toner nearempty
100
50-150
M
Adjusts the threshold value for displaying remaining
amount of toner and toner near empty. Display threshold
value = default threshold value x setting value/100 (unit: %)
50: Setting value x 0.5
100: Setting value x 1.0
150: Setting value x 1.5
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Fusing correction
control time
immediately after
warming-up
5210
0
Temperature correction
2
0-10
M
0: Disable 1: 1 min. 2: 2 min. 3: 3 min. 4: 4 min. 5: 5 min. 6:
6 min. 7: 7 min. 8: 8 min. 9: 10 min. 10: 15 min.
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Fusing correction
control time
immediately after
warming-up
5210
1
Maximum time of lamp
ON
2
0-10
M
0: Disable 1: 1 min. 2: 2 min. 3: 3 min. 4: 4 min. 5: 5 min. 6:
6 min. 7: 7 min. 8: 8 min. 9: 10 min. 10: 15 min.
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Correction of
temperature rising
prevention (Latest
value)
5337
0
Ready
0
0-15
M
0: 0
o
C 1: -1
o
C 2: -2
o
C 3: -3
o
C 4: -4
o
C 5: -5
o
C 6: -6
o
C 7:
-7
o
C 8: -8
o
C 9: -9
o
C 10: -10
o
C 11: -11
o
C 12: -12
o
C 13: -
13
o
C 14: -14
o
C 15: -15
o
C
14
Y
Y
Y
08
Setting
mode
Process
Fuser
Correction of
temperature rising
prevention (Latest
value)
5337
1
Printing
0
0-15
M
0: 0
o
C 1: -1
o
C 2: -2
o
C 3: -3
o
C 4: -4
o
C 5: -5
o
C 6: -6
o
C 7:
-7
o
C 8: -8
o
C 9: -9
o
C 10: -10
o
C 11: -11
o
C 12: -12
o
C 13: -
13
o
C 14: -14
o
C 15: -15
o
C
14
Y
Y
Y
08
Setting
mode
Process
Fuser
5469
-
Low power
consumption control
1
0-1
M
This code is used when using low power consumption
control. Note that inconsistent fusing may occur if the fuser
roller temperature is low. Use the above default value,
unless otherwise required.
0: Invalid, 1: Valid
1
Y
Y
Y
08
Setting
mode
Process
Fuser
5497
0
Low power
consumption control:
Lamp maximum ON
time (Center)
10
1-50
M
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5497
1
Low power
consumption control:
Lamp maximum ON
time (Side)
10
1-50
M
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5497
2
Low power
consumption control:
Lamp maximum ON
time (Center)
10
1-50
M
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-2-61
e-STUDIO2303A/2303AM/2803AM/2309A/2809A
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)