4
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
DISASSEMBLY AND REPLACEMENT
4 - 47
4.6.17
Paper empty sensor (S5)
(1) Open the right cover.
(2) Take off the drawer.
(3) Take off the duct unit.
(4) Take off the registration roller (metal)
P. 4-44 "4.6.14 Registration roller (metal)"
(5) Remove one screw and then slide the
registration guide [1] towards the rear and
remove it.
Fig. 4-121
Notes:
When installing the registration guide, insert
the latch at the rear side into the damp
heater bracket [2], slide it to the front side,
and then insert the two bosses into the damp
heater bracket.
Fig. 4-122
(6) Remove 1 screw and then take off the damp
heater unit or dummy plate [3] while sliding it
to the rear and lifting it down.
Fig. 4-123
[1]
[2]
[3]