e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
REMOTE SERVICE <20H/23H/25H, 23HA/28HA>
10 - 2
10.1.2
Setting
[A] Setting items
Notes:
1. Service notification setting (08-9793) and service notification display (08-9604) must be set to
“1”.
2. When using this function, it is required that sending and receiving E-mails are available.
Confirm the details to the administrator.
3. This function will not be performed even if all settings are turned ON (valid) while the power of
the equipment is turned OFF or the equipment is in the Sleep mode during the specified time.
To use this function, do not turn the power of the equipment OFF in the specified time or do
not set the time for this function during the Sleep mode set period.
Set the Service Notification setting in the following setting mode(08).
Items
08 code
Contents
Service Notification setting
9793
0: OFF (Invalid)
1: ON (Valid)
Total Counter Transmit setting
9795
0: OFF (Invalid)
1: ON (Valid)
Total counter transmission “day of
the week” setting
9881
0: OFF (Invalid)
1: Saturday
2: Friday
4: Thursday
8: Wednesday
16: Tuesday
32: Monday
64: Sunday
Multiple days of the week can be
set by setting the SUM of the
values for the day of the week.
Service notification display
9604
Displays “SERVICE
NOTIFICATION” in the INITIAL
SETUP menu. When “1” is set,
operation and setting are made
available for users.
0: OFF
1: ON
Service call transmission
9605
When this function is enabled, it
notifies the error code
corresponding to the service call
by E-mail.
0: OFF
1: ON
Total counter transmission interval
setting
(Hour/Hour/Minute/Minute)
9606
00:00-23:59
PM Counter Transmit setting
9797
0: OFF (Invalid)
1: ON (Valid)
Total counter transmission date
setting 1
9796
0: OFF (Invalid)
1 to 31: Date
Total counter transmission date
setting 2
9880
0: OFF (Invalid)
1 to 31: Date
Toner near-empty Transmit
(23HA/28HA Only)
8538
0: OFF (Invalid)
1: ON (Valid)