SETTING / ADJUSTMENT
6 - 3
(5) Check if the value B is within the range of 234 to 246 (the output voltage range of the auto-toner
sensor is 2.34 V to 2.46 V).
(6) If the value B is not within the range of 234 to 246, press the Up or Down button to adjust the
value manually.
Notes:
The relation between the button and the values A and B is as follows.
(7) Press the [OK] button.
The drum, developer unit, etc. are stopped and the following is displayed.
Fig.6-5
(8) Turn the power OFF.
(9) Install the toner cartridge.
Button to be pressed
Value A
Value B
Up
Increased
Increased
Down
Decreased
Decreased
MC=
[OK]
TEST MODE A