05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
23LA
23LM/
28LM
23HA/
28HA
08
Setting
mode
Process
Fuser
Fuser roller
temperature during
printing (Center
thermistor)
2194
-
Envelope
13
0-14
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees
C 12: 200 degrees C 13: 205 degrees C 14: 210
degrees C
1
Y
Y
Y
08
Setting
mode
Process
Fuser
Fuser roller
temperature during
printing (Side
thermistor)
2195
-
Envelope
11
0-14
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees
C 12: 200 degrees C 13: 205 degrees C 14: 210
degrees C
1
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Center
thermistor)
Thick paper
2198
0
The first drop
20
0-200
M
Setting value x 5 seconds later: from 0 to 1000 seconds
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Center
thermistor)
Thick paper
2198
1
The second drop
30
0-200
M
Setting value x 5 seconds later: from 0 to 1000 seconds
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Center
thermistor)
Thick paper
2198
2
The third drop
40
0-200
M
Setting value x 5 seconds later: from 0 to 1000 seconds
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Center
thermistor)
Thick paper
2198
3
The fourth drop
75
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Side
thermistor)
Thick paper
2199
0
The first drop
4
0-200
M
Setting value x 5 seconds later: from 0 to 1000 seconds
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Side
thermistor)
Thick paper
2199
1
The second drop
30
0-200
M
Setting value x 5 seconds later: from 0 to 1000 seconds
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Side
thermistor)
Thick paper
2199
2
The third drop
40
0-200
M
Setting value x 5 seconds later: from 0 to 1000 seconds
4
Y
Y
Y
e-STUDIO2303A/2303AM/2803AM/2309A/2809A
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
14-2-34
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved