e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 30
6.5.2
Gamma balance adjustment <20H/23H/25H, 23HA/28HA>
The density is adjusted by adjusting the gamma balance. The adjustment is performed by selecting its
density area from the following: low density, medium density and high density.
<Adjustment Mode (05)>
Notes:
Changing the adjustment setting influences the adjacent density area slightly.
E.g.: When the value of the medium density is larger, the adjacent areas in the low density and
high density range will become slightly darker.
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the codes to be adjusted (language and screen) and press the [START] button.
(3) Key in the value corresponding to the density area to be adjusted (0, 1 or 2) and press the
[START] button.
0: Low density 1: Medium density 2: High density
(4) Key in an adjustment value. (To correct the value once keyed in, press the [CLEAR/STOP]
button.)
(5) Press the [OK] button to store the value in memory. The equipment goes back to the test mode A
screen.
(6) For resetting the value, repeat step (2) to (5).
(7) Turn the power OFF and then back ON to perform printing job.
(8) If the image density has not been attained, repeat step (2) to (7).
Color
mode
Smooth
Detail
Item to be adjusted
Remarks
(PCL)
(PCL)
Black
(600dpi)
7317-0
7318-0
Low density
The larger the value is, the density of
the item to be adjusted becomes
darker.
Acceptable values: 0 to 255
(Default: 128)
7317-1
7318-1
Medium density
7317-2
7318-2
High density