(3) If the image skew is "C" as shown in the figure below, turn the screw in the direction of "-", and if
"D", turn it to "+".
Notes:
Turning the screw exceeding 1.5 scales or more in the "+" or "-" direction may cause a paper jam.
(4) When the adjustment is finished, reattach the platen sheet.
(5) After the RADF is closed, visually check that there is no gap between the top cover of the
scanner and the foot portions of the RADF.
If the gap is not appropriate, the adjustment range may be exceeded. In this case, turn the screw
in the "+" direction until the gap becomes appropriate.
Fig.6-33
Notes:
Be sure to reattach the platen sheet at any time after turning the screw.
Fig.6-31
Fig.6-32
Turn the screw in the direction of "-".
Turn the screw in the direction of "+".