8
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
ERROR CODE AND TROUBLESHOOTING
8 - 15
8.3
Diagnosis and Prescription for Each Error Code
8.3.1
Check item
Check item
Contents
Sensor check
• Check the sensor in the test mode.
• Check that there is no dust on the sensor.
• Check that the actuator is correctly operated.
Connector check
• Check that the connector is not disconnected.
• Check that the pins are not deformed and do not come off.
• Disconnect and reconnect the connector.
Harness check
• Check if the harnesses are open circuited.
Motor check
• Check the motor in the test mode.
• Check that there is no abnormality in the driving section.
• Check that there is no abnormality in the roller.
Board check
• Check if the board is short circuited or open circuited.