05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
23LA
23LM/
28LM
23HA/
28HA
08
Setting
mode
Process
Fuser
2090
-
Printing temperature
drop control
1
0-6
M
0: Invalid
1: (Normal temperature / Low temperature) Plain paper and
Thick paper 1 Valid
2: (Normal temperature / Low temperature) Valid (except
for Envelope)
3: (Normal temperature) Plain paper and Thick paper 1
Valid
4: (Normal temperature / Low temperature)Plain paper
5: (Normal temperature) Plain paper
6: (Normal temperature) Valid (except for Envelope)
1
Y
Y
Y
08
Setting
mode
Process
Fuser
2100
-
Temperature setting of
warming-up (Center
thermistor)
5
0-14
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C 3:
155 degrees C 4: 160 degrees C 5: 165 degrees C 6:
170 degrees C 7: 175 degrees C 8: 180 degrees C 9:
185 degrees C 10: 190 degrees C 11: 195 degrees C
12: 200 degrees C 13: 205 degrees C 14: 210 degrees C
1
Y
Y
Y
08
Setting
mode
Process
Fuser
2101
-
Temperature setting of
warming-up (Side
thermistor)
5
0-14
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees C
12: 200 degrees C 13: 205 degrees C 14: 210 degrees
C
1
Y
Y
Y
08
Setting
mode
Process
Fuser
2111
-
Pre-running time
(Normal temperature)
0
0-18
M
0: Disabled 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5
sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec.
11: 15 sec. 12: 20 sec. 13: 25 sec. 14: 30 sec. 15: 40
sec. 16: 50 sec. 17: 60 sec. 18: 150 sec.
1
Y
Y
Y
08
Setting
mode
Process
Fuser
2120
-
Fuser roller
temperature in ready
status (Side thermistor)
8
0-12
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees
C 12: 200 degrees C
1
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready
status (Side
thermistor)
2121
0
The first drop
4
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready
status (Side
thermistor)
2121
1
The second drop
4
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready
status (Side
thermistor)
2121
2
The third drop
4
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready
status (Side
thermistor)
2121
3
The fourth drop
4
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-2-31
e-STUDIO2303A/2303AM/2803AM/2309A/2809A