4
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
DISASSEMBLY AND REPLACEMENT
4 - 19
4.3.4
CIS case <23LA/23LM/28LM/23HA/28HA>
(1) Take off the CIS unit.
P. 4-15 "4.3.2 Contact Image Sensor unit
(2) Remove the tension spring [1].
Fig. 4-47
(3) Take off 1 pulley [2] and CIS case [3].
Notes:
When replacing the pulley, apply
Molykote (EM-30L) between the
tensioner and pulley shaft.
Fig. 4-48
(4) Take off the CIS case [3].
Notes:
If the spring comes off, it is attached black
spring [5] to the front side, and brown
spring [6] to the rear side.
Fig. 4-49
[1]
[2]
[3]
[5]
[6]