e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 2
6.2
Adjustment of Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
<Procedure> (Adjustment Mode (05-2000))
(1) Install the developer unit into the equipment.
(2) While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
Fig.6-2
(3) Key in code [2000] and press the [START] button.
The display changes as follows.
Fig.6-3
Notes:
B indicates the output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
(4) After about two minutes, the value B automatically starts changing.
Fig.6-4
Notes:
A indicates the controlled value of the auto-toner sensor output. Press the Up or Down button to
change the value.
MC=
[0][5]
[POWER]
TEST MODE A
[2000]
[START]
B
MC=2000
WAIT
230
TEST MODE A
MC=2000
TEST MODE A
A
B
245 128