7
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
PREVENTIVE MAINTENANCE (PM)
7 - 9
Fig. 7-10
Remove the used EPU from
the equipment. Set the new
EPU in the equipment, then
close the front cover.
Start auto-toner sensor
adjustment.
OK
OK
OK
EPU MODE
REMOVE
EPU MODE
DEV. CARTRIDGE
OPEN FRONT COVER
CARTRIDGE
EPU MODE
CLOSE FRONT COVER
SET TONER
EPU MODE
PRESS [OK]
EPU MODE
SET A4/LT IN DRAWER
PRESS [OK]
EPU MODE
PRINTING
CLOSE COVER
EPU MODE
PRESS [OK]
SET TEST CHART
EPU MODE
WAIT
EPU MODE
TURN OFF THE POWER
Starts EPU mode
Step 0
Step 1
Step 2
Step 3
Step 4
Step 5
Load A4 or LT size paper into
the cassette, set the cassette
paper size, then turn OFF the
power.
Turn ON the power while
pressing [Function clear] and
[START] buttons.
Open the front cover, then
set the toner cartridge.
Press [OK].
Press [OK].
Place the printed gamma chart
on the original glass, then
press [OK].
Press the [ON/OFF] button
for a few seconds.
Operation flow
Display transition of control panel
Behavior flow of equipment
Automatic toner
adjustment
Clears counters of
consumables in the EPU
Prints the gamma chart
Reads the gamma chart,
then performs automatic
gamma adjustment
Power off
When the authentication
screen appears, enter a service
password and press [OK].
The authentication screen is
displayed. Press the [OK].
The developer material is filled
from the developer cartridge.